    (H)RW5 – 40.5 Outdoor Expulsion Drop-out Type Distribution Drop-out Fuse Cutout Series For 11-15kv

    Categories:

    Contact Now
    (H)RWW5-40.5 series outdoor high-voltage drop-out fuse cutout(hereinafter referred to as “fuse”) is the most common short-circuit protection switch for distribution line branch and distribution transformer. The fuse is suitable for short circuit and overload protection of transmission lines and power transformers in the power system with AC 50Hz and a rated voltage of 35kV. Under certain conditions, a no-load overhead line, no-load transformer, and small load current can be opened and closed. Drop-out Fuses cutout are widely used in distribution lines and the primary side of distribution transformers as protection and equipment switching operations. It is installed on the branch of the distribution line to reduce the scope of power failure. Product Advantage 1. Insulating porcelain bushing or silicone rubber composite bushing are designed with large creepage distance, with strong pollution resistance and environmental adaptability, and good insulation performance, which can meet the requirements of long-distance travel in altitude areas. 2. Welding pipe replacement is simple and convenient 3. Fast fusing, good performance and large breaking capacity Technical Parameters
    No. Item Unit Technical Parameters
    1 Rated Frequency Hz 50/60
    2 Rated Voltage kV 40.5
    3 Rated Current of Fuse of the same family A 100 200
    4 Rated Breaking Current MVA 6 8
    5 Rated Short-Time Power Frequency WithstandVoltage (1-min) kV/min 95/1(To Earth)
    118/1  (Fracture)
    6 Rated Lightning Impulse Withstand Voltage kV 185(To Earth)
    215(Voltage)
    7 Creepage distance mm More than 1256
    8 Mechanical Life Times 300
    If the altitude is over 1000m,the rated insulation level should be modified as appropriate
    USAGE USAGE: ENVIRONMENTAL CONDITION 1. Altitude: No more than 4000m 2. The ambient temperature is not higher than + 40 ºC and not lower than – 40 ºC 3. There is a clear disconnection point with the function of isolating switch, which creates a safe working environment for the maintenance line and equipment and increases the safety of maintenancepersonnel; 4. Simple structure, high-cost performance ratio, convenient operation, and easy maintenance; 5. The product is not applicable to the following places:Places with burning or explosion hazards;Places with violent vibration or impact;Areas with conductive chemical gas and serious pollution and salt fog. 6. Strong adaptability to the outdoor environment; 7. Large climbing distance design to meet the operation requirements in high-altitude areas Outline and Dimension

    Request Inquery

    Request a Quote

    Contact Us

  • Hebei Shiyue Electrical Equipment Co., Ltd.
  • +86 15369772778240164684@qq.com
  • 450 meters east from the Shijialiancheng Village Committee in Shaozhuang Township, Suning County, Cangzhou City, Hebei Province, on the north side of the road
  • Copyright © 2026 Hebei Shiyue Electrical Equipment Co., Ltd. All Rights Reserved.

    Contact Us
    whatsapp

    Request Inquery